Publication Details

Category Text Publication
Reference Category Journals
DOI 10.1016/j.talanta.2008.10.062
Title (Primary) Dynamic fractionation of trace metals in soil and sediment samples using rotating coiled column extraction and sequential injection microcolumn extraction: A comparative study
Author Rosende, M.E.; Savonina, E.Y.; Fedotov, P.S.; MirĂ³, M.; Cerda, V.; Wennrich, R.
Source Titel Talanta
Year 2009
Department ANA
Volume 79
Issue 4
Page From 1081
Page To 1088
Language englisch
Keywords Dynamic fractionation; Rotating column; Microcolumn extraction; Trace elements; Soil; Sediment
Abstract Dynamic fractionation has been recognized as an appealing alternative to conventional equilibrium-based sequential extraction procedures (SEPs) for partitioning of trace elements (TE) in environmental solid samples. This paper reports the first attempt for harmonization of flow-through dynamic fractionation using two novel methods, the so-called sequential injection microcolumn (SIMC) extraction and rotating coiled column (RCC) extraction. In SIMC extraction, a column packed with the solid sample is clustered in a sequential injection system, while in RCC, the particulate matter is retained under the action of centrifugal forces. In both methods, the leachants are continuously pumped through the solid substrates by the use of either peristaltic or syringe pumps.A five-step SEP was selected for partitioning of Cu, Pb and Zn in water soluble/exchangeable, acid-soluble, easily reducible, easily oxidizable and moderately reducible fractions from 0.2 to 0.5 g samples at an extractant flow rate of 1.0 mL min-1 prior to leachate analysis by inductively coupled plasma-atomic emission spectrometry.Similarities and discrepancies between both dynamic approaches were ascertained by fractionation of TE in certified reference materials, namely, SRM 2711 Montana Soil and GBW 07311 sediment, and two real soil samples as well. Notwithstanding the different extraction conditions set by both methods, similar trends of metal distribution were in generally found. The most critical parameters for reliable assessment of mobilisable pools of TE in worse-case scenarios are the size-distribution of sample particles, the density of particles, the content of organic matter and the concentration of major elements. For reference materials and a soil rich in organic matter, the extraction in RCC results in slightly higher recoveries of environmentally relevant fractions of TE, whereas SIMC leaching is more effective for calcareous soils.
Persistent UFZ Identifier https://www.ufz.de/index.php?en=20939&ufzPublicationIdentifier=540
Rosende, M.E., Savonina, E.Y., Fedotov, P.S., MirĂ³, M., Cerda, V., Wennrich, R. (2009):
Dynamic fractionation of trace metals in soil and sediment samples using rotating coiled column extraction and sequential injection microcolumn extraction: A comparative study
Talanta 79 (4), 1081 - 1088 10.1016/j.talanta.2008.10.062