Publication Details

Category Text Publication
Reference Category Journals
DOI 10.1016/j.scitotenv.2016.07.059
Title (Primary) Downscaling procedures reduce chemical use in androgen receptor reporter gene assay
Author Di Paolo, C.; Kirchner, K.; Balk, F.G.P.; Muschket, M.; Brack, W.; Hollert, H.; Seiler, T.-B.
Source Titel Science of the Total Environment
Year 2016
Department WANA
Volume 571
Page From 826
Page To 833
Language englisch
Keywords Downscaling; Miniaturization; Low-volume; Androgen receptor binders; Reporter gene bioassay; (Anti)androgens
UFZ wide themes RU2;
Abstract Bioactivity screening studies often face sample amount limitation with respect to the need for reliable, reproducible and quantitative results. Therefore approaches that minimize sample use are needed. Low-volume exposure and chemical dilution procedures were applied in an androgen receptor reporter gene human cell line assay to evaluate environmental contaminants and androgen receptor modulators, which were the agonist 5α-dihydrotestosterone (DHT); and the antagonists flutamide, bisphenol A, 1-hydroxypyrene and triclosan. Cells were exposed in around 1/3 of the medium volume recommended by the protocol (70 μL/well). Further, chemical losses during pipetting steps were minimized by applying a low-volume method for compound dilution in medium (250 μL for triplicate wells) inside microvolume glass inserts. Simultaneously, compounds were evaluated following conventional procedures (200 μL/well, dilution in 24-well plates) for comparison of results. Low-volume exposure tests produced DHT EC50 (3.4–3.7 × 10− 10 M) and flutamide IC50 (2.2–3.3 × 10− 7 M) values very similar to those from regular assays (3.1–4.2 × 10− 10 and 2.1–3.3 × 10− 7 M respectively) and previous studies. Also, results were within assay acceptance criteria, supporting the relevance of the downscaling setup for agonistic and antagonistic tests. The low-volume exposure was also successful in determining IC50 values for 1-hydroxypyrene (2.1–2.8 × 10− 6 M), bisphenol A (2.6–3.3 × 10− 6 M), and triclosan (1.2–1.9 × 10− 6 M) in agreement with values obtained through high-volume exposure (2.3–2.8, 2.5–3.4 and 1.0–1.3 × 10− 6 M respectively). Finally, experiments following both low-volume dosing and exposure produced flutamide and triclosan IC50 values similar to those from regular tests. The low-volume experimental procedures provide a simple and effective solution for studies that need to minimize bioassay sample use while maintaining method reliability. The downscaling methods can be applied for the evaluation of samples, fractions or chemicals which require minimal losses during the steps of pipetting, transference to medium and exposure in bioassays.
Persistent UFZ Identifier https://www.ufz.de/index.php?en=20939&ufzPublicationIdentifier=17926
Di Paolo, C., Kirchner, K., Balk, F.G.P., Muschket, M., Brack, W., Hollert, H., Seiler, T.-B. (2016):
Downscaling procedures reduce chemical use in androgen receptor reporter gene assay
Sci. Total Environ. 571 , 826 - 833 10.1016/j.scitotenv.2016.07.059