Titel (primär) Post column infusion of internal standard to LC-FT-ICR MS enables semi-quantitative comparison of dissolved organic matter in original samples
Autor Rodrigues Matos, R.; Jennings, E.K.; Kaesler, J.; Reemtsma, T.; Koch, B.P.; Lechtenfeld, O.J. ORCID logo
Quelle Analyst
Erscheinungsjahr 2024
Department EAC
Band/Volume 149
Heft 12
Seite von 3468
Seite bis 3478
Sprache englisch
Topic T9 Healthy Planet
Supplements https://www.rsc.org/suppdata/d4/an/d4an00119b/d4an00119b1.pdf
Keywords Natural organic matter; Reversed-phase liquid chromatography; Fourier transform ion cyclotron resonance mass spectrometry; Terrestrial organic carbon cycle; River network
UFZ Querschnittsthemen ProVIS;
Abstract Ultrahigh resolution mass spectrometry hyphenated with liquid chromatography (LC) is an emerging tool to explore the isomeric composition of dissolved organic matter (DOM). However, matrix effects limit the potential for semi-quantitative comparison of DOM molecule abundances across samples. We introduce a post-column infused internal standard (PCI-IS) for reversed-phase LC-FT-ICR MS measurements of DOM and systematically evaluate matrix effects, detector linearity and the precision of mass peak intensities. Matrix effects for model compounds spiked into freshwater DOM samples ranging from a headwater stream to a major river were reduced by 5–10% for PCI-IS corrected mass peak intensities as compared to raw (i.e., untransformed) intensities. A linear regression of PCI-IS corrected DOM mass peak intensities across a typical DOM concentration range (2–15 mg dissolved organic carbon L−1) in original, non-extracted freshwater samples demonstrates excellent linearity of the detector response (r2 > 0.9 for 98% of detected molecular formulas across retention times). Importantly, PCI-IS could compensate for 80% of matrix effects across an environmental gradient of DOM composition from groundwater to surface water. This enabled studying the ionization efficiency of DOM isomers and linking the observed differences to the biogeochemical sources. With PCI-IS original, non-extracted DOM samples can be analysed by LC-FT-ICR MS without carbon load adjustment, and mass peak intensities can be reliably used to semi-quantitatively compare isomer abundances between compositionally similar DOM samples.
dauerhafte UFZ-Verlinkung https://www.ufz.de/index.php?en=20939&ufzPublicationIdentifier=29075
Rodrigues Matos, R., Jennings, E.K., Kaesler, J., Reemtsma, T., Koch, B.P., Lechtenfeld, O.J. (2024):
Post column infusion of internal standard to LC-FT-ICR MS enables semi-quantitative comparison of dissolved organic matter in original samples
Analyst 149 (12), 3468 - 3478 10.1039/D4AN00119B