Details zur Publikation

Kategorie Textpublikation
Referenztyp Zeitschriften
DOI 10.3390/ijms18112484
Titel (primär) Development of an impedimetric aptasensor for the detection of Staphylococcus aureus
Autor Reich, P.; Stoltenburg, R.; Strehlitz, B.; Frense, D.; Beckmann, D.
Quelle International Journal of Molecular Sciences
Erscheinungsjahr 2017
Department BOOEK; UBZ
Band/Volume 18
Heft 11
Seite von art. 2484
Sprache englisch
Keywords aptamer; staphylococcal protein A; label-free; biosensing techniques; rapid detection; self-assembly; limit of detection; protein binding; ferri-/ferrocyanide; gold electrode
UFZ Querschnittsthemen RU1;
Abstract In combination with electrochemical impedance spectroscopy, aptamer-based biosensors are a powerful tool for fast analytical devices. Herein, we present an impedimetric aptasensor for the detection of the human pathogen Staphylococcus aureus. The used aptamer targets protein A, a surface bound virulence factor of S. aureus. The thiol-modified protein A-binding aptamer was co-immobilized with 6-mercapto-1-hexanol onto gold electrodes by self-assembly. Optimization of the ratio of aptamer to 6-mercapto-1-hexanol resulted in an average density of 1.01 ± 0.44 × 1013 aptamer molecules per cm2. As shown with quartz crystal microbalance experiments, the immobilized aptamer retained its functionality to bind recombinant protein A. Our impedimetric biosensor is based on the principle that binding of target molecules to the immobilized aptamer decreases the electron transfer between electrode and ferri-/ferrocyanide in solution, which is measured as an increase of impedance. Microscale thermophoresis measurements showed that addition of the redox probe ferri-/ferrocyanide has no influence on the binding of aptamer and its target. We demonstrated that upon incubation with various concentrations of S. aureus, the charge-transfer resistance increased proportionally. The developed biosensor showed a limit of detection of 10 CFU·mL−1 and results were available within 10 minutes. The biosensor is highly selective, distinguishing non-target bacteria such as Escherichia coli and Staphylococcus epidermidis. This work highlights the immense potential of impedimetric aptasensors for future biosensing applications.
dauerhafte UFZ-Verlinkung https://www.ufz.de/index.php?en=20939&ufzPublicationIdentifier=19592
Reich, P., Stoltenburg, R., Strehlitz, B., Frense, D., Beckmann, D. (2017):
Development of an impedimetric aptasensor for the detection of Staphylococcus aureus
Int. J. Mol. Sci. 18 (11), art. 2484 10.3390/ijms18112484