Details zur Publikation

Kategorie Textpublikation
Referenztyp Zeitschriften
DOI 10.1029/2007WR006075
Titel (primär) Breakthrough of attenuating contaminant plumes in pumping wells: Analytical model and implications for integral pumping tests
Autor Bayer-Raich, M.; Jarsjö, J.; Teutsch, G.
Quelle Water Resources Research
Erscheinungsjahr 2009
Department GF; HDG
Band/Volume 45
Heft 2
Seite von W02413
Sprache englisch
Abstract Monitoring of contaminant plumes and predicting their future fate are essential for effective management of groundwater contaminants. Solute breakthrough curves from operating pumping wells can provide information on the water quality in relatively large aquifer regions, which may be unavailable to instrumentation and direct measurement for practical and/or economical reasons. Relations between spatially varying aquifer concentrations C 0(x, y) initially surrounding a well and temporally varying concentrations of subsequently extracted well water, C (t), then need to be quantified. However, limited applicability of analytical expressions and numerical inaccuracies related to solving transport equations for converging flow fields hamper such quantifications even in homogeneous aquifers. We use a stream-tube approach and provide a general problem formulation that accounts for first-order degradation and linear, instantaneous, sorption/retardation in heterogeneous aquifers. An analytical expression is obtained for homogeneous aquifer conditions (in the well vicinity), relating any given initial C 0(x, y) function and the subsequent contaminant breakthrough C (t) in the well. Results for wide plumes subject to first-order degradation show that concentrations at the extraction well will increase as a function of pumping time. This increase is despite the fact that late-time data reflect longer transport paths (to the well), along which mass is removed through degradation. We also derive unique solutions for the inverse problem, in particular considering how the average contaminant concentration C (averaged along a control plane through the well within its capture zone, perpendicular to the mean groundwater flow direction) depends on the measurable C (t). The solutions demonstrate that the longer the pumping time, the more sensitive the solutions for C become to degradation rate constants, which if needed can be determined in situ using multiple control planes.
dauerhafte UFZ-Verlinkung https://www.ufz.de/index.php?en=20939&ufzPublicationIdentifier=45
Bayer-Raich, M., Jarsjö, J., Teutsch, G. (2009):
Breakthrough of attenuating contaminant plumes in pumping wells: Analytical model and implications for integral pumping tests
Water Resour. Res. 45 (2), W02413 10.1029/2007WR006075